Cassette selection guide
Medical X-Ray Cassettes: Types, Selection and Care
An X-ray cassette looks simple, but its job is exacting: protect the image receptor, keep it correctly positioned and support repeatable image quality. The right choice starts with one distinction—screen-film, computed radiography and direct digital radiography are not the same technology.

Three technologies
Film-screen and CR use cassettes. DR normally uses an integrated or cassette-size flat-panel detector.
Compatibility first
A cassette’s dimensions alone do not prove that its plate and reader are compatible.
Condition matters
Dust, scratches, poor contact and physical damage can create artefacts and repeat examinations.
What an X-ray cassette actually does
A cassette is a rigid, light-protective carrier for an image receptor. In a conventional screen-film system, it holds the film in close contact with intensifying screens. In computed radiography, it protects a reusable photostimulable phosphor plate until the plate is read and erased by the CR reader.
That distinction matters because “digital cassette” is often used loosely. A CR cassette is a cassette. A direct-radiography flat panel is an electronic detector; some panels are made in familiar cassette dimensions, but their electronics, integration and service requirements are completely different. The IAEA guidance on CR and direct radiography describes CR plates as cassette-based receptors and direct radiography as a separate flat-panel technology.
| Technology | What receives the exposure | What happens next | Typical procurement check |
|---|---|---|---|
| Screen-film | Film between intensifying screens in a light-tight cassette | Chemical processing creates the visible image | Film/screen spectral match, size and processor chemistry |
| Computed radiography | Photostimulable phosphor plate inside a cassette | A CR reader scans and erases the plate for reuse | Reader family, plate type, cassette size and condition |
| Direct radiography | Flat-panel detector | The image appears electronically without a cassette reader step | Detector, generator and software integration |
Standard cassette and imaging plate sizes
Cassette and plate formats are quoted in both metric and imperial units, and the two are rounded conversions rather than exact equivalents. These are the formats MEDELEM stocks.
| Metric format | Imperial format |
|---|---|
| 18 × 24 cm | 7 × 9.5 in |
| 20 × 25 cm | 8 × 10 in |
| 15 × 30 cm | 6 × 12 in |
| 24 × 30 cm | 10 × 12 in |
| 25 × 30 cm | 10 × 12 in |
| 28 × 35 cm | 11 × 14 in |
| 35 × 35 cm | 14 × 14 in |
| 35 × 43 cm | 14 × 17 in |
Two metric formats are both sold as 10 × 12 in: 24 × 30 cm and 25 × 30 cm. Confirm the metric dimension rather than the imperial label, and confirm that the reader accepts that cassette format.
Three technologies that are often confused
Screen-film cassettes
These cassettes form part of an analogue imaging chain. The film, intensifying screens, cassette contact and chemical processor all influence the final hardcopy. A replacement therefore has to be selected as part of the system—not simply by matching the outer dimensions.
Computed radiography cassettes
CR uses a reusable imaging plate inside a light-tight cassette. After exposure, the reader extracts or scans the plate, converts the stored signal into a digital image, erases the residual image and returns the plate for reuse. This preserves familiar cassette handling while producing an electronic result.
Direct radiography detectors
DR removes the separate cassette-reader step. The flat-panel detector converts the exposure into an electronic image that is available at the workstation. Wireless panels may share the 35 × 43 cm format used by cassettes, but they are not interchangeable with CR plates.
Interactive comparison
Which receptor system are you working with?
Select a technology to see the first checks that matter before procurement.
Verify the complete film-screen system
Confirm cassette size, intensifying-screen type, film spectral sensitivity and processor chemistry. Treat these parts as one imaging chain.
Match the cassette and imaging plate to the reader
Check the exact reader family, plate specification and supported cassette format. A cassette that fits physically may still contain the wrong plate.
Procure a detector, not a CR cassette
A cassette-size DR panel is an electronic detector. Confirm generator integration, detector interface, software and service support.
How cassette condition affects image quality
A cassette can remain usable for years, but only if its condition is monitored. Dirt or damage on a CR plate may create repeatable artefacts. Poor screen-film contact can reduce local sharpness. Warped housings, damaged hinges or light leaks can also compromise performance.
Good practice is practical rather than glamorous: identify every cassette, inspect the housing, clean only with the manufacturer-approved method, review recurring artefacts and include plates in the facility’s quality-control programme. The IAEA quality-control guidance notes that imaging plates should be cleaned first when tolerances are exceeded and replaced when defects remain clinically significant.
Protect the receptor
Do not stack heavy equipment on cassettes or leave plates exposed to heat, moisture and contamination.
Track repeat artefacts
If the same mark appears with the same cassette, remove it from clinical use until it is checked.
Follow the IFU
Cleaning materials and replacement criteria should come from the cassette or reader manufacturer.
How to choose a medical X-ray cassette
- 1
Identify the imaging system
Record the X-ray system and, for CR, the reader manufacturer and exact model. If you only know the old cassette reference, photograph its label—not patient information.
- 2
Confirm receptor type
Establish whether you need screen-film, a CR cassette and imaging plate, or a DR detector. The answer changes the entire specification.
- 3
Verify size and application
Check metric and imperial formats, body-part workflow and any dedicated requirements such as mammography or dental imaging.
- 4
Check compatibility in writing
Ask the supplier to confirm the reader family, plate type and cassette format. Do not rely on “universal” unless the manufacturer explicitly supports it.
- 5
Plan inspection and replacement
Include cleaning, identification, artefact review and a route for replacing damaged plates in the purchase decision.
Cassettes and radiation safety: the precise relationship
A cassette does not make an examination safe by itself. Patient dose depends on justification, technique selection, equipment performance and quality assurance. Some cassette designs include backing that helps reduce backscatter reaching the receptor, but this should not be described as protection for staff.
The FDA medical X-ray imaging guidance recommends using the lowest radiation dose that still provides image quality adequate for the diagnostic or interventional task. Facilities should follow their local radiation-protection rules and the equipment manufacturer’s procedures.
The future is a managed mix, not a single replacement
Direct radiography continues to expand because it shortens the path from exposure to image. CR still provides a practical upgrade route for installed X-ray rooms that use standard cassette formats. Screen-film remains in some legacy and resource-constrained environments, although its processing and quality-control needs are greater.
For a buyer, the sensible question is not “Which technology is newest?” It is “Which receptor fits the installed equipment, workload, service capacity and quality-assurance programme?” That answer may differ between a hospital, a mobile unit and a distributor supporting several markets.
Frequently asked questions
Is a CR cassette the same as an X-ray film cassette?
No. The housings can look similar, but a CR cassette contains a reusable photostimulable imaging plate, while a conventional cassette holds film and intensifying screens.
Can any CR cassette work with any CR reader?
No. Reader family, cassette mechanics, plate specification and software identification can differ. Confirm the exact combination before ordering.
When should a CR imaging plate be replaced?
Replace it when damage or persistent artefacts remain after approved cleaning and the plate no longer meets the facility’s quality-control criteria.
Sources and further reading
- IAEA guidance on CR and direct radiography — distinction between CR cassette plates and flat-panel detectors.
- IAEA quality-control guidance — inspection, artefacts and quality-control considerations for imaging plates.
- FDA medical X-ray imaging guidance — justification, optimisation and quality assurance in medical X-ray imaging.
Procurement support
Send the model. We’ll help narrow the correct product.
Include the equipment manufacturer and model, current media reference, size, quantity and destination country. Our team will check the request before quotation.